project profile

The certain CO., Ltd. (hereinafter referred to as party A) and Shandong Xunda chemical group CO., Ltd. (hereinafter referred to as party B) sign the following contract based on the propylene refining unit of 450 thousand t/year polypropylene equipment which purchase molecular sieve, desulfurizer, ceramic ball and steel net.

propylene refining

service

1. All products must confirm to the designed standards selected.

2. The product provided by party B should sufficiently consider the reliability, safety and economic of equipment operation, select excellent material. After signature, party A has right to propose some supplemental requirements because of the change of specification, standards and rules, the specific content is negotiated by both parties.

3. Party B should supply goods according to the bidding standards, the product technical indexes reach the purchase technical requirements of party A. this contract for technology will be the technical attachment after signing purchase contract and an effective part of contract.

4. Party B produces product according to the bidding requirements and national standards.

5. when party B supply goods, the relevant qualified certificate should be transported with goods, including product quality inspection report, MSDS and operation introduction.

6. All quality inspection certificates should be sealed with new seal of quality inspection department.

 

service

performance guarantee

Various operating elasticity based on designed basis required (the most elasticity is 120%, that is satisfying the following conditions at the most operating situation), each guarantee value of 3A molecular sieve, A911 COS hydrolysis, Z919 ZnO desulfurizer and inert ceramic ball is as follows:

1. Lifetime: at the beginning of introduction, the guarantee period of 3A, A911, Z919 is 4 years and the lifetime is 5 years

2. Impurity removal performance: at the designed processing conditions, inlet overall sulfur content is less than 0.5ppm/mol, dew point is less than -80℃. Removal accuracy of impurity at propylene inlet and outlet see in table 1:

Table 1 Pre-removal accuracy of impurity in propylene refining unit

Composition

Inlet content

Outlet content

Total Sulfur

2 ppm wt, max

0.5 ppm wt, max

Total Alcohols

10 ppm mol, max

0.5 ppm mol, max

Carbonyl Sulfide

1 ppm mol, max

0.05 ppm mol, max

Water

40 ppm mol, max

1 ppm mol, max

3. absorption period and pressure drop:

Table 2 Absorption period and pressure drop of molecular sieve

Equipment NO.

Absorption period

Pressure drops of operating end-stage

COS hydrolysis equipment D-1002

4 years

≤30KPa

ZnO desulfurization equipment D-1003

2 years

≤20KPa

Water removal equipment of molecular sieve D-1006A/B

≥60 days

≤20KPa

performance

property indexes

Table 1 A911

Quality standards

Appearance

White sphere

Specification, mm

φ3~5

Bulk density, Kg/L

0.7~0.9

Specific surface area, m2/g

≥200

Compressive strength, N/granule

≥75

Conversion rate of organic sulfur, %

≥95.0

 

Table 2 Z919

Quality standards

Appearance

Gray strip

Specification, mm

Φ (3~5) × (5~25)

Bulk density, Kg/L

0.8~1.1

Compressive strength, N/cm

≥70

Sulfur capacity, %(m/m)

≥10.0

 

Table 3 3A molecular sieve

Project

Technical index

Specification, mm

F 3-5

Wear rate, % <

0.40

Bulk density, g/ml >

0.68

Particle size, % >

96.0

Static water adsorption, % >

21.0

Compressive strength, N/granule <

80.0

Compressive strength coefficient of variation <

0.3

Dynamic water adsorption, % >

20.0

Static propylene adsorption, mg/g <

3.0

Water content of package, % <

1.5

 

Table 4 Inert ceramic ball

Test projects

Technical index

Appearance

No cracks, no flaws, no bubbles

Size

13 mm, 25 mm sphere

Sudden temperature change resistance (℃)

>1700

Bulk density (g/ml)

>1.8

Wear rate (%wt)

<0.05

Compressive strength (N/granule)

φ13 mm: >1800; φ25 mm: >6200

Pore volume (um)

>40

Water adsorption rate (%)

<5

Acid resistance (%)

>98

Alkali resistance (%)

>97

A911

Z919

3A molecular sieve

inert ceramic ball

package and attachment mark

 

A911, Z919, 3A molecular sieve provided by party B should be sealed packaging with tons bag, inert ceramic ball should be packaged in woven bag, and the product inspection report should be transport with them. The marks like name and batch number should be marked on obvious place, writing should clear.

The packaging of 3A molecular sieve: jumbo bag, ≤ 1400kg/bag.

The packaging of A911, Z919: jumbo bag, ≤ 1400kg/bag.

Inert ceramic ball: 25kg/bag.

The package will be returned after the loading is completed.

package