project profile

The certain branch of Sinopec (hereinafter referred to as: party A) wants to use Z919 refining desulfurizer produced by Shandong Xunda chemical group CO., Ltd. at sulfur removal unit for propylene (at oil refining department 2), therefore, satisfying the desulfurization requirements of sulfur removal unit for propylene of party A. To make the product reach the expected effect and clear responsibility of both sides, both sides achieve the consensus and sign this contract through technical conversation and sufficient negotiation.

desulfurization equipment

Z919

Table 1 Technical indexes and test method of Z919 refining desulfurizer

Quality standards

Processing conditions and purification indexes

Appearance

Gray strip

Operating temperature, ℃

Normal temperature

Specification, mm

Φ (3~5) × (5~25)

Operating pressure, MPa

Normal pressure~8.0

Bulk density, kg/L

0.8~1.1

Height-to-diameter ratio, L/D

≥3

Compressive strength, N/cm

≥70

Space velocity, h-1

Liquid phase <5

Sulfur capacity, %(m/m)

≥10.0

   
Z919

performance guarantee

The product provided satisfy the performance indexes mentioned, inspection rate of purchase product is 100%, the unqualified will return.

Party B provides "qualified certificate", "test inspection report", "Material Safety Data Sheet (MSDS)" and the "commercial contract" showed by other manufactures and so on files.

Party B promises that the catalyst used won't make negative impaction to the unit of party A.

performance

service

Provide qualified refining desulfurizer according to the requirements of party A. provide product, quality inspection report and acceptance qualified certificate of refining desulfurizer that strictly according to the commercial contract signed with party A and technical quality indexes of this contract.

Provide relevant occupational health, industrial safety and technical advice of environmental protection of the use for refining desulfurizer and relevant information, such as the method of quality inspection, enterprise standards, MSDS, operation introduction (include use and cautions) and the quality guarantee period.

Give answer to relevant technical problem proposed by party A in 24 hours. Provide free technical service according to the requirements of party A during the use of product (include start and exceptions treatment). 

Promise that the product provided to party A won't violate intellectual property and other benefit of any third party.

service