Load top-down in layers, put the cheapest robust material where the poisons arrive, and never place a fresh high-activity grade directly under a sulfur condenser outlet. The first 300 mm of a tail gas reactor does more filtering than catalysing.
A tail gas reactor sees a hostile feed: sulfur mist, ammonium salts, entrained amine, occasional hydrocarbon slugs, and whatever the converters let through on a bad day. The whole train is the last barrier in front of the stack, so a Claus Tail Gas Treatment stage that starts clean does not stay clean. Bed design follows the grading logic of any hydrotreater, scaled for a low-pressure vessel.
Inert ceramic balls, 10–13 mm - spread inlet flow and hold the bed down through upsets
Sacrificial guard layer - coarse, high-voidage material to catch sulfur mist and salts before they blind the active bed
Hydrogenation catalyst, main volume - size it on Space velocity, typically 200–1,500 h⁻¹ dry gas
Hydrolysis catalyst layer where organic sulfur is high
Support stack - 6 mm, then 13 mm, then 25 mm balls up to the grid, each layer no more than twofold coarser than the one above
Four rules prevent most failures:
Sieve before loading. Transport generates fines, and unscreened material at the top of a bed is the fastest route to rising ΔP.
Do not walk on the bed. Crushed granules become dust, dust becomes pressure drop, and pressure drop becomes an unplanned shutdown. Use load-bearing boards.
Pressure-test before start-up. Differential pressure across the catalyst bed should sit within 10% of design; anything wider means channelling or compaction.
Keep the organic-sulfur layer loaded. Where Raw gas carries COS and CS₂ at inlet, the hydrolysis layer is not optional - a bare tail gas hydrogenation catalyst bed passes them straight to the amine unit as mercaptans that re-enter the sulfur loop.
For presulfiding, run a two-stage in-situ programme: hold near 220–250 °C where most sulfur uptake occurs and CoO converts to Co₉S₈, then ramp to 310–330 °C where MoO₂S converts to MoS₂. A single fast ramp risks reducing the metals to their elemental state instead of sulfiding them, permanently costing activity. Ex-situ presulfided grades cut start-up time, but confirm your unit tolerates the residual hydrocarbon carrier.
✅ Bottom line: Layer the bed by poison exposure and sieve before loading; most short bed lives are mechanical, not chemical.
The same chemistry earns its place in several other duties, and buyers who standardise on one family cut qualification effort:
|
Duty |
Feed |
What the bed removes |
Xunda grade |
|
Coke-oven gas upgrading |
Coke oven gas |
Organic sulfur, CO, olefins |
XDH-2 |
|
Coking dry gas |
Coker off-gas |
Olefins and sulfur before H₂ recovery |
XDH-4 |
|
Ammonia / methanol feed |
Natural gas, LPG, naphtha |
Organic sulfur plus arsenic |
XDH-1, XDH-3 |
Two details decide whether one of these beds works. Selective hydrodesulfurisation of FCC gasoline is a different animal from tail gas work: the goal is stripping sulfur compounds down to hydrogen sulfide without saturating olefins, so the grade must preserve octane. And guard beds ahead of reforming are sized on contaminant loading, not nominal throughput - a 200 ppm arsenic feed needs a different volume than a clean one, whatever the reactor nameplate says.
As a China manufacturer holding 55 invention patents and a provincial enterprise technology centre, Xunda Catalyst produces standard and custom-promoted grades across these families. Shandong Xunda Catalyst Co., Ltd. supplies PetroChina, Sinopec, CNOOC and BP operations as well as overseas refineries, with OEM formulation, bulk pricing and trial quantities for first-time buyers.
✅ Bottom line: Standardise on one catalyst family across guard-bed duties to cut qualification cost, but never reuse a tail gas grade ahead of reforming.