Do not roll the catalyst on the ground during transportation to prevent it from crushing.

 

Open the catalyst barrel and leave 10ml of sample in each barrel. Mix and analyze the catalyst.

 

After opening the barrel, decide whether to sieve based on the condition of the catalyst.

 

The catalyst must be loaded according to the design height.

 

The catalyst must be poured into the loading hopper and loaded into the reactor using a canvas bag. When handling the catalyst, it should be handled gently and the iron drum should not be rolled.

 

Personnel participating in the loading process must strictly guard against bringing other items into the reactor, such as keys, knives, iron wires, and lead wires.

 

Personnel entering the reactor must obtain a certificate and wear dust masks.

 

Before entering the reactor, sample and analyze the gas inside the reactor. If it is qualified, it is allowed to enter the reactor. The reactor must be isolated from the system with blind plates.